Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Med. crít. (Col. Mex. Med. Crít.) ; 33(4): 189-195, jul.-ago. 2019. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1287131

ABSTRACT

Resumen: Introducción: Las variables hemodinámicas nos informan sobre la progresión de lesión renal aguda (AKI por sus siglas en inglés). Material y métodos: Estudio prospectivo, observacional, longitudinal, de pacientes ingresados a la Unidad de Terapia Intensiva del 2017 al 2018. Se incluyeron mayores de 18 años, con lesión renal aguda (AKI 1 o 2), monitoreo hemodinámico de tensión arterial media (TAM), tensión arterial diastólica (PAD), frecuencia cardiaca (FC) y de presión venosa central (PVC). Determinados desde las 24 horas del diagnóstico hasta el egreso. Resultados: Fueron 164 pacientes, 105 (64%) presentaron progresión de AKI cuando TAM < 75.98 mmHg. PAD < 61, PVC >8 cm H2O, FC > 90 x', TAM-PVC < 67.64 mmHg, PAD-PVC < 53.28 mmHg. Conclusiones: La TAM, PAD y la PVC tienen el mayor impacto en el riesgo de progresión de AKI cuando se calcula la presión de perfusión media con estas variables.


Abstract: Introduction: Haemodynamic variables inform us about the progression of acute kidney injury (AKI). Material and methods: Prospective, observational and longitudinal study of patients admitted to Intensive Care (ICU) from 2017-2018. patients over 18 years were included, with acute kidney injury (AKI 1, 2), and hemodynamic monitoring of mean arterial blood pressure (MAP), diastolic blood pressure (DBP), heart rate (HR) and central venous pressure (CVP). Determined from 24 hours after diagnosis and its evolution was recorded until discharge. Results: A total of 164 patients were included, progression of AKI presented when MAP < 75.98 mmHg, DBP < 61 mmHg, CVP < 8 cmH2O, FC 90 x', MAP-CVP 67.64 mmHg, DBP-CVP 53.28 mmHg, HR > 90 beats/minute. Conclusions: MAP, DBP and CVP have the greatest impact on the risk of AKI progression, especially when the mean perfusion pressure (PPM) is calculated with these two variables.


Resumo: Introdução: As variáveis hemodinâmicas informam sobre a progressão da lesão renal aguda (LRA). Materiais e métodos: Estudo prospectivo, observacional, longitudinal de pacientes admitidos em terapia intensiva (UTI) de 2017-2018. Foram incluídos pacientes maiores de 18 anos, com lesão renal aguda (LRA 1 ou 2), monitorização hemodinâmica da pressão arterial média (TAM), pressão arterial diastólica (PAD), freqüência cardíaca (FC) e pressão venosa central (PVC). Determinada a partir de 24 horas de diagnóstico até a alta. Resultados: 164 pacientes (p), 105 p (64%) apresentaram progressão da LRA quando TAM < 75.98 mmHg, PAD < 61 mmHg, PVC > 8 cmH2O, FC > 90 x´, TAM-PVC < 67.64 mmHg, PAD- PVC < 53.28 mmHg. Conclusões: TAM, PAD e PVC têm o maior impacto no risco de progressão da LRA quando a pressão média de perfusão (PMP) é calculada com essas variáveis.

2.
Arq. bras. cardiol ; 108(4): 297-303, Apr. 2017. tab
Article in English | LILACS | ID: biblio-838718

ABSTRACT

Abstract Background: Atrial fibrillation (AF) takes place in 10-40% of patients undergoing coronary artery bypass grafting (CABG), and increases cardiovascular mortality. Enlargement of atrial chambers is associated with increased AF incidence, so patients with higher central venous pressure (CVP) are expected to have larger atrial distension, which increases AF incidence. Objective: To compare post-CABG AF incidence, following two CVP control strategies. Methods: Interventional, randomized, controlled clinical study. The sample comprised 140 patients undergoing CABG between 2011 and 2015. They were randomized into two groups, G15 and G20, with CVP maintained ≤ 15 cmH2O and ≤ 20 cmH2O, respectively. Results: 70 patients were included in each group. The AF incidence in G15 was 8.57%, and in G20, 22.86%, with absolute risk reduction of 14.28%, and number needed to treat (NNT) of 7 (p = 0.03). Mortality (G15 = 5.71%; G20 = 11.42%; p = 0.07), hospital length of stay (G15 = 7.14 days; G20 = 8.21 days; p = 0.36), number of grafts (median: G15 = 3, G2 = 2; p = 0.22) and cardiopulmonary bypass use (G15 = 67.10%; G20 = 55.70%; p = 0.22) were statistically similar. Age (p = 0.04) and hospital length of stay (p = 0.001) were significantly higher in patients who developed AF in both groups. Conclusion: Keeping CVP low in the first 72 post-CABG hours reduces the relative risk of AF, and may be useful to prevent AF after CABG.


Resumo Fundamento: A fibrilação atrial (FA) ocorre em 10-40% dos pacientes submetidos a cirurgia de revascularização miocárdica (RM), e eleva a mortalidade cardiovascular. Como o aumento dos átrios está associado ao aumento da incidência de FA, espera-se que pacientes com pressão venosa central (PVC) mais alta tenham maior distensão atrial, o que eleva a incidência dessa arritmia. Objetivo: Comparar a incidência de FA em pós-operatório de RM, seguindo duas estratégias de controle de PVC. Métodos: Estudo clínico randomizado controlado intervencionista. A amostra foi composta por 140 pacientes submetidos a RM entre 2011 e 2015. Os pacientes foram randomizados em dois grupos, G15 e G20, mantidos com PVC máxima de 15 cmH2O e 20 cmH2O, respectivamente. Resultados: Foram incluídos 70 pacientes em cada grupo. A incidência da arritmia em G15 foi de 8,57% e, no G20, de 22,86%, com redução de risco absoluto de 14,28% e número necessário para tratar (NNT) de 7 (p = 0,03). Mortalidade (G15 = 5,71%; G20 = 11,42%; p = 0,07), tempo de internamento (G15 = 7,14 dias; G20 = 8,21 dias; p = 0,36), número de enxertos (medianas: G15 = 3, G2 = 2; p = 0,22) e uso de circulação extracorpórea (G15 = 67,10%; G20 = 55,70%; p = 0,22) mostraram-se estatisticamente semelhantes. A idade (p = 0,04) e o tempo de internamento (p = 0,001) foram significativamente maiores nos pacientes que desenvolveram FA nos dois grupos. Conclusão: Manter a PVC com valores mais baixos nas primeiras 72h após a cirurgia de RM reduz o risco relativo de FA e pode ser uma ferramenta útil na prevenção da FA após RM.


Subject(s)
Humans , Male , Female , Middle Aged , Atrial Fibrillation/etiology , Atrial Fibrillation/prevention & control , Central Venous Pressure/physiology , Coronary Artery Bypass/adverse effects , Postoperative Period , Atrial Fibrillation/epidemiology , Central Venous Pressure/drug effects , Coronary Artery Bypass/mortality , Incidence , Prospective Studies , Age Factors , Diuretics/administration & dosage , Furosemide/administration & dosage , Length of Stay/statistics & numerical data
3.
Rev. bras. oftalmol ; 75(2): 156-159, Mar.-Apr. 2016. graf
Article in Portuguese | LILACS | ID: lil-779967

ABSTRACT

RESUMO As fístulas carótido-cavernosas são uma causa rara, porém grave, de glaucoma secundário por aumento da pressão venosa episcleral. Apresenta-se um caso de uma mulher de 72 anos, negra, atendida no Hospital de Clínicas da Universidade Federal do Triângulo Mineiro (HC-UFTM) com dor, sensação de pulsação, proptose, engurgitamento episcleral e quemose em olho direito, com aumento da pressão intraocular (PIO) apesar do uso de mediação anti-glaucomatosa. Na arteriografia foi evidenciada fístula dural para o seio cavernoso à direita, com refluxo para as veias orbitárias ipsilaterais. Realizou-se tratamento com agente líquido de embolização e, após o tratamento cirúrgico, apresentou melhora completa da proptose e congestão dos vasos episclerais, porém manteve PIO aumentada e desenvolvimento de glaucoma de ângulo fechado pela presença de goniossinéquias em 270º, com controle satisfatório com medicação.


ABSTRACT Carotid-cavernous fistulas are a major cause of secondary glaucoma due to increased episcleral venous pressure. We present the case of a 72-year-old female patient, treated at the Hospital de Clínicas at the Universidade Federal do Triângulo Mineiro (HC-UFTM), with pain, proptosis, episcleral engorgement, chemosis and pulsation in the right eye, with increased intraocular pressure (IOP) on anti-glaucomatous medication.Arteriography showed dural fistula to the right cavernous sinus, with reflux to orbital veins.Treatment with liquid embolization agent was performed, following full recovery of proptosis and congestion of the episcleral vessels. However, the patient maintained increased IOP because of narrow-angle glaucoma development due to the presence of goniosynechiae in 270º, which was controlled satisfactorily with medication.


Subject(s)
Humans , Female , Aged , Glaucoma/etiology , Ocular Hypertension/complications , Carotid-Cavernous Sinus Fistula/complications , Polyvinyls/administration & dosage , Magnetic Resonance Imaging , Catheterization , Angiography , Dimethyl Sulfoxide/administration & dosage , Carotid-Cavernous Sinus Fistula/therapy , Carotid-Cavernous Sinus Fistula/diagnostic imaging , Embolization, Therapeutic/methods
4.
Rev. enferm. UERJ ; 24(1): e14502, jan.-fev. 2016. ilus
Article in Portuguese | LILACS, BDENF | ID: biblio-947054

ABSTRACT

Objetivo: identificar se existe diferença nos valores da pressão venosa central com a cabeceira do leito do paciente elevada. Método: estudo longitudinal, analítico e de abordagem quantitativa, realizado em quatro unidades de terapia intensiva de um hospital de grande porte do noroeste paulista, de agosto a novembro de 2013. A pressão venosa central foi mensurada em 156 pacientes, em quatro angulações diferentes, totalizando 624 medidas. Os dados são apresentados em números absolutos e percentuais, as variáveis analisadas pelo Teste de Mann-Whitney e Wilcoxon e associação entre as medidas pela análise do coeficiente de correlação de Pearson (r). Conclusão: a mensuração pode ser realizada com acurácia a 0° e 30°, pois apresentaram correlação positiva entre as medidas, porém a 0° e 45° a correlação é fraca, demonstrando pouca associação entre as variáveis.


Objective: to investigate whether central venous pressure values differ with patient bed inclination. Method: this quantitative, analytical, longitudinal study was conducted from November to August 2013 at four intensive care units at a large hospital in northwest São Paulo. Central venous pressure was measured in 156 patients at four different bed inclinations each, totaling 624 measurements. The data are expressed in absolute and percentage values, variables were analyzed using the Mann-Whitney and Wilcoxon tests, and associations between measurements were tested by Pearson's correlation coefficient (r). Conclusion: measurements were found to be accurate at 0° and 30° (a positive correlation between measurements), but a weak correlation at 0° and 45° (revealing little association between the variables).


Objetivo: identificar si existen diferencias de valores de la presión venosa central dependiendo de la altura de la cabecera de la cama del paciente. Método: el estudio es cuantitativo, analítico y longitudinal, realizado en cuatro unidades de cuidados intensivos de un hospital de gran porte, ubicado en el Noroeste del São Paulo entre agosto y noviembre de 2013. Se midió la presión venosa central en 156 pacientes, desde cuatro ángulos diferentes, totalizando 624 mediciones. Los datos se presentan en números absolutos y en porcentajes; las variables fueron analizadas mediante la Prueba de Mann­Whitney­Wilcoxon y la asociación entre las medidas se hizo a través del análisis del coeficiente de correlación de Pearson (r). Conclusión: la medición pudo realizarse con exactitud a 0° y 30° grados, ya que presentan una correlación positiva entre las medidas. Sin embargo, a 0° y a 45° grados, la correlación fue débil mostrando poca asociación entre las variables.


Subject(s)
Humans , Blood Volume , Central Venous Pressure , Critical Care , Nursing Care , Longitudinal Studies , Intensive Care Units
5.
Rev. bras. ter. intensiva ; 27(4): 340-346, out.-dez. 2015. tab, graf
Article in English | LILACS | ID: lil-770039

ABSTRACT

RESUMO Objetivos: Testar se amostras de sangue venoso coletadas do acesso femoral podem ser utilizadas para estimar a saturação venosa central de oxigênio e os níveis de lactato arterial em pacientes graves. Métodos: Foram utilizadas a análise de Bland-Altman e correlações de Spearman para comparar a saturação venosa femoral de oxigênio e a saturação venosa central de oxigênio, assim como os níveis de lactato arterial e femoral. Foi conduzida uma análise predeterminada de subgrupos nos pacientes com sinais de hipoperfusão. Além disso, foi também investigada a concordância clínica. Resultados: Foram obtidas amostras sanguíneas de 26 pacientes. Em 107 amostras pareadas, observou-se correlação moderada (r = 0,686; p < 0,0001) entre a saturação venosa central de oxigênio e a saturação venosa femoral de oxigênio, com um viés de 8,24 ± 10,44 (limites de concordância de 95%: -12,23 a 28,70). Em 102 amostras pareadas, houve forte correlação entre os níveis arteriais de lactato e os níveis de lactato femoral (r = 0,72, p < 0,001) com um viés de -2,71 ± 9,86 (limites de concordância de 95%: -22,3 a 16,61). A presença de hipoperfusão não modificou de forma significante os resultados. A concordância clínica para saturação venosa foi inadequada, com diferentes decisões terapêuticas em 22,4% das situações; para o lactato, isto ocorreu em apenas 5,2% das situações. Conclusão: A saturação venosa de oxigênio femoral não deve ser utilizada em substituição da saturação venosa central de oxigênio. No entanto, os níveis femorais de lactato podem ser utilizados na prática clínica, mas com cautela.


ABSTRACT Objectives: The purpose of this study was to test if venous blood drawn from femoral access can be used to estimate the central venous oxygen saturation and arterial lactate levels in critically ill patients. Methods: Bland-Altman analysis and Spearman correlations were used to compare the femoral venous oxygen saturation and central venous oxygen saturation as well as arterial lactate levels and femoral lactate. A pre-specified subgroup analysis was conducted in patients with signs of hypoperfusion. In addition, the clinical agreement was also investigated. Results: Blood samples were obtained in 26 patients. In 107 paired samples, there was a moderate correlation (r = 0.686, p < 0.0001) between the central venous oxygen saturation and femoral venous oxygen saturation with a bias of 8.24 ± 10.44 (95% limits of agreement: -12.23 to 28.70). In 102 paired samples, there was a strong correlation between the arterial lactate levels and femoral lactate levels (r = 0.972, p < 0.001) with a bias of -2.71 ± 9.86 (95% limits of agreement: -22.03 to 16.61). The presence of hypoperfusion did not significantly change these results. The clinical agreement for venous saturation was inadequate, with different therapeutic decisions in 22.4% of the situation; for lactate, this was the case only in 5.2% of the situations. Conclusion: Femoral venous oxygen saturation should not be used as a surrogate of central venous oxygen saturation. However, femoral lactate levels can be used in clinical practice, albeit with caution.


Subject(s)
Humans , Male , Female , Aged , Oxygen/blood , Blood Gas Analysis/methods , Critical Illness , Lactic Acid/blood , Catheterization, Central Venous , Prospective Studies , Femoral Vein , Middle Aged
6.
Rev. bras. ter. intensiva ; 25(2): 168-174, abr.-jun. 2013. tab
Article in Portuguese | LILACS | ID: lil-681997

ABSTRACT

A utilização da saturação venosa central de oxigênio (SvcO2) e do lactato arterial no diagnóstico de hipoperfusão tecidual em doentes graves já está bem estabelecida, e a otimização desses parâmetros é buscada principalmente em pacientes com sepse grave/choque séptico. Contudo, em diversas ocasiões, o único sítio para punção venosa profunda ou a primeira escolha para punção é a veia femoral. Embora a saturação venosa obtida da coleta de sangue desse cateter, em substituição a SvcO2, já tenha sido utilizada, pouco se sabe a respeito da acurácia de seus resultados. A utilização do lactato venoso, em substituição da punção arterial, também tem norteado decisões terapêuticas. Realizamos esta revisão de literatura buscando evidências sobre a correlação e a concordância desses parâmetros, obtidos pela coleta de gasometria venosa femoral, em relação à SvcO2 e ao lactato arterial. Existem poucos estudos na literatura avaliando a utilização da saturação venosa femoral de oxigênio (SvfO2) ou de lactato venoso. Os resultados até então obtidos mostram não haver concordância adequada entre SvfO2 e SvcO2, o que limita sua utilidade clínica. No entanto, a aparente correlação forte entre os valores de lactato arterial e venoso, tanto periférico como central, sugere que o lactato venoso obtido da veia femoral poderia, eventualmente, ser utilizado em substituição do lactato arterial, embora não haja evidências suficientes para basear essa conduta no momento.


The use of central venous oxygen saturation (SvcO2) and arterial lactate in the diagnosis of severe tissue hypoperfusion is well established, and the optimization of these parameters is currently under investigation, particularly in patients with severe sepsis/septic shock. However, the only place for deep venous puncture or the first choice for puncture is often the femoral vein. Although venous saturation obtained from blood sampling from this catheter, instead of SvcO2, has already been used in the diagnosis of severe tissue hypoperfusion, little is known about the accuracy of the results. The venous lactate in place of arterial puncture has also been used to guide therapeutic decisions. We conducted this literature review to seek evidence on the correlation and concordance of parameters obtained by collecting femoral venous blood gases in relation to SvcO2 and arterial lactate. Few studies in the literature have evaluated the use of femoral venous oxygen saturation (SvfO2) or venous lactate. The results obtained thus far demonstrate no adequate agreement between SvfO2 and SvcO2, which limits the clinical use of SvfO2. However, the apparent strong correlation between arterial and peripheral and central venous lactate values suggests that venous lactate obtained from the femoral vein could eventually be used instead of arterial lactate, although there is insufficient evidence on which to base this procedure at this time.


Subject(s)
Humans , Catheterization, Central Venous/methods , Lactic Acid/blood , Oxygen/blood , Blood Gas Analysis/methods , Femoral Vein , Sepsis/complications , Sepsis/physiopathology , Shock, Septic/complications , Shock, Septic/physiopathology
7.
Rev. bras. oftalmol ; 72(1): 46-49, jan.-fev. 2013. ilus
Article in Portuguese | LILACS | ID: lil-667598

ABSTRACT

O objetivo é relatar o caso de uma paciente de 33 anos, que veio ao Pronto Socorro de Oftalmologia apresentando queixa de redução da acuidade visual à esquerda, de caráter insidioso e progressivo, há dois anos. Ao exame oftalmológico, apresentava ingurgitamento dos vasos da conjuntiva bulbar, pressão intraocular muito elevada e nervo óptico com escavação total à esquerda. Foi submetida à campimetria computadorizada 24:2 WW e SITA-SWAP do olho direito, ambas com resultados dentro da normalidade. As tomografias de crânio e órbitas, bem como ultrassonografia com doppler do globo ocular, artérias oftálmicas e veias supraorbitárias não apresentavam anormalidades. Diante disso, aventou-se a hipótese diagnóstica de hipertensão venosa episcleral idiopática, um diagnóstico de exclusão, visto que patologias intracranianas e intraorbitárias haviam sido excluídas. Paciente foi tratada clinicamente com colírios hipotensores, com redução importante da pressão intraocular à esquerda, porém não o suficiente, evoluindo para trabeculectomia.


The objective is to report a 33 year old female who came to the emergency room of Ophthalmology complaining of reduced visual acuity on the left eye, in a progressive and insidious way, about two years ago. In the ophthalmological examination, she presented dilated tortuous vessels in her left bulbar conjunctiva, very high intraocular pressure and increased cupping of the optic disc. SITA-SWAP and 24:2 computed perimetry were performed on the right eye, both within normal limits. CT scans of the skull and orbits, and ultrasonography of the eyeball and doppler of the ophthalmic artery and the supra-orbital veins had no abnormalities. Thus, it was suggested the possibility of idiopathic elevated episcleral venous pressure, an exclusion diagnosis, since intra-cranial and intraorbital pathologies were excluded. The patient was treated medically with hypotensive eyedrops, with significant reduction of intraocular pressure on the left eye, but not enough, evolving to trabeculectomy.


Subject(s)
Humans , Female , Adult , Antihypertensive Agents/therapeutic use , Glaucoma, Open-Angle , Intraocular Pressure , Trabeculectomy , Timolol/therapeutic use , Ultrasonography, Doppler , Venous Pressure
8.
Arq. bras. oftalmol ; 76(1): 45-47, jan.-fev. 2013. ilus
Article in English | LILACS | ID: lil-678162

ABSTRACT

Radius-Maumenee syndrome comprises idiopathic dilated episcleral vessels that are usually associated with glaucoma. The case described herein is of a male patient, 69 years old, with chronic dilation of the episcleral vessels and glaucoma in his left eye, with no history of systemic disease. Visual acuity and fundoscopy were normal in both eyes. Tonometry measured 14 mmHg in the right eye and 25 mmHg in the left. Computed tomography angiography (CTA) was negative for carotid-cavernous fistula. The intraocular pressure of the left eye decreased to 20 mmHg with clinical treatment without regression of episcleral venous dilation. Trabeculectomy normalized the intraocular pressure and reduced the vessels. There was choroidal effusion on day 16 of the postoperative period, which resolved with corticosteroids. Although choroidal effusion can occur, the efficacy of trabeculectomy in controlling glaucoma and the reduction of episcleral vessels are clearly demonstrated.


A síndrome de Radius-Maumenee consiste na dilatação idiopática dos vasos episclerais geralmente associada ao glaucoma. Descreve-se o caso de paciente masculino, 69 anos, portador de dilatação crônica dos vasos episclerais e glaucoma do olho esquerdo, sem histórico de doença sistêmica. A acuidade visual e fundoscopia apresentaram-se normais em ambos os olhos. A tonometria mediu 14 mmHg no olho direito e 25 mmHg no esquerdo. A angiotomografia foi negativa para fístula carotídeo-cavernosa. A pressão intraocular do olho esquerdo diminuiu para 20 mmHg com tratamento clínico, sem regressão da dilatação venosa episcleral. A trabeculectomia normalizou a pressão intraocular e reduziu os vasos. Houve efusão coroidiana no 16º dia de pós-operatório que regrediu com corticoterapia. Embora possa ocorrer efusão coroidiana, destaca-se a eficácia da trabeculectomia no controle do glaucoma e na redução dos vasos episclerais.


Subject(s)
Female , Humans , Male , Middle Aged , Glaucoma, Open-Angle/physiopathology , Intraocular Pressure/physiology , Sclera/blood supply , Glaucoma, Open-Angle/surgery , Syndrome , Trabeculectomy , Treatment Outcome , Venous Pressure/physiology
9.
Rev. Esc. Enferm. USP ; 46(spe): 107-115, out. 2012. ilus
Article in Portuguese | LILACS, BDENF | ID: lil-659838

ABSTRACT

O objetivo do estudo foi desenvolver e avaliar um aplicativo multimídia em plataforma móvel para o ensino da Mensuração da Pressão Venosa Central (PVC). A pesquisa foi desenvolvida em três fases (Levantamento das necessidades; Metodologia de desenvolvimento do aplicativo multimídia e Avaliação do aplicativo multimídia). A multimídia foi o método escolhido por favorecer um ambiente motivador e dinâmico, integrar imagens e textos num aplicativo disponível para celulares, constituindo-se um meio móvel e autônomo de aprendizagem. Os resultados permitem demonstrar a viabilidade do desenvolvimento da ferramenta para subsidiar a prática pedagógica e abrem perspectivas para acreditar que, na educação em Enfermagem, a tecnologia disponível pode descortinar novos modos de aprender significativamente.


This study aimed to develop and assess an application software for the teaching of the procedure Manual Measurement of the Central Venous Pressure which can be used in mobile devices. The research was conducted in three phases (Survey of needs; Methodology for multimedia application development and evaluation of the multimedia application).The multimedia was the method chosen because it favors an encouraging and dynamic environment, as it integrates images and texts into an application software available for cell phones, constituting a mobile and autonomous means for learning. The research allowed to demonstrate the feasibility of the development from this pedagogical tool and open up prospects for believing that, in Nursing education, the technology available can uncover new ways of learning in a meaningful manner.


El objetivo del estudio fue desarrollar y evaluar una aplicación multimedia en la plataforma móvil para la enseñanza Medición de la Presión Venosa Central (PVC). La investigación se llevó a cabo en tres fases (estudio de las necesidades, metodología para el desarrollo de aplicaciones multimedia y evaluación de la aplicación multimedia). Multimedia fue el método elegido para proponer un ambiente dinámico y motivador, la integración de imágenes y texto en una aplicación disponible en los teléfonos móviles, convirtiendo-se en un medio de aprendizaje móvil y autónomo. Los resultados nos permiten demostrar la viabilidad de desarrollar una herramienta para apoyar la práctica docente y abrir perspectivas para creer que la educación en Enfermería, la tecnología disponible puede descubrir nuevas formas de aprendizaje de manera significativa.


Subject(s)
Adult , Female , Humans , Male , Young Adult , Blood Pressure Determination , Computer-Assisted Instruction , Education, Nursing/methods , Multimedia , Central Venous Pressure
10.
Rev. bras. cir. cardiovasc ; 23(4): 488-493, out.-dez. 2008. graf, tab
Article in English, Portuguese | LILACS | ID: lil-506031

ABSTRACT

OBJETIVO: É comum a obtenção de acesso venoso femoral em pacientes submetidos a cirurgia cardíaca em associação ou como alternativa ao acesso superior (veia jugular interna ou veia subclávia). O objetivo deste estudo foi comparar as medidas de pressão venosa central (PVC) em dois sítios diferentes (superior vs. femoral). MÉTODOS: Estudo prospectivo e aberto com 60 pacientes submetidos a cirurgia cardíaca no período de julho a novembro de 2006. Foram obtidas três medidas de cada paciente em cada sítio (admissão, 6 e 12 horas após a cirurgia) em duas inclinações diferentes da cabeceira do leito (zero e 30 graus), totalizando 720 medidas. RESULTADOS: Cinqüenta e cinco por cento dos pacientes foram submetidos a revascularização do miocárdio, 38 por cento a cirurgia valvar e 7 por cento a outras cirurgias. A média de PVC ± desvio padrão (DP) medida no acesso superior foi de 13,0 ± 5,5 mmHg (zero grau) e 13,3 ± 6,1 mmHg (30 graus), enquanto que as medidas no acesso inferior foram 11,1 ± 4,9 mmHg (zero grau) e 13,7 ± 4,6 mmHg (30 graus). A correlação linear (r) entre as medidas nos dois sítios foi de 0,66 (zero grau) e 0,53 (30 graus), ambas com p < 0,0001. CONCLUSÃO: A PVC pode ser medida com acurácia no acesso venoso femoral no pós-operatório imediato de cirurgia cardíaca, com melhor correlação linear obtida com as medidas feitas com a cabeceira do leito posicionada em zero grau.


OBJECTIVE: It is common to obtain femoral venous approach in patients undergoing combined heart surgery or as an alternative to superior approach (internal jugular vein or subclavian vein). The aim of this study was to compare the measures of central venous pressure (CVP) at two different sites (superior versus femoral). METHODS: We prospectively and openly allocated 60 patients who underwent heart surgery between July from November 2006. Three measures were obtained from each patient at each site (admission, 6 and 12 hours after surgery) in two different inclinations of the headboard (zero and 30 degrees) totaling 720 measures. RESULTS: Fifty five percent of patients who underwent coronary artery bypass grafting, 38 percent heart valve surgery and 7 percent other surgeries. The mean of CVP ± standard deviation (SD) measured in superior approach was 13.0 ± 5.5 mmHg (zero degree) and 13.3 ± 6.1 mmHg (30 degrees) while the measures in inferior approach were 11.1 ± 4.9 mmHg (zero degree) and 13.7 ± 4.6 mmHg (30 degrees). The linear correlation (r) between the measures in both sites was 0.66 (zero degree) and 0.53 (30 degrees), both with p value<0.0001. CONCLUSION: The CVP can be measured with accuracy in the femoral venous approach in the immediate postoperative period of heart surgery with better linear correlation obtained with the measures made with the headboard positioned at zero degree.


Subject(s)
Female , Humans , Male , Middle Aged , Cardiac Surgical Procedures , Catheterization, Central Venous/methods , Central Venous Pressure/physiology , Femoral Vein/physiology , Jugular Veins/physiology , Subclavian Vein/physiology , Beds , Epidemiologic Methods , Postoperative Period , Posture , Preoperative Care , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL